Skip to main content

患者定位和运动管理,SGRT

SGRT – Patient positioning and motion management

Catalyst+HD™ offers a complete solution for online patient tracking before and during treatment delivery, thus ensuring the best possible treatment outcome without non-prescribed doses.

THE TREATMENT WORKFLOW

Non-rigid Algorithm

While SGRT systems are used for final positioning, body tattoos and room lasers are typically used for initial setup, meaning that only three points on the skin surface are the basis for setting up the whole patient. Correcting a setup error means that the patient position must be shifted manually, followed by an additional check for laser and tattoo alignment. It is typically not possible to detect posture errors or misalignment of patient extremities with a classic  ”3 point set up”.

Catalyst+HD™ captures the complete body surface continuously. The Non-Rigid Registration Algorithm compares the current patient posture to the previously recorded reference setup in real time.

Deviations are immediately projected directly onto the patient’s skin, ensuring a fully interactive work flow. Catalyst+HD™ communicates directly with the couch to support the auto set-up procedure. The system is designed for a maximum level of integration into the treatment process.

View Catalyst+HD™ products

Setup and Positioning

  • 3D surface positioning
  • Patented color map projected on patient body during setup
  • Correct any posture or positioning errors immediately

Motion management in real time

  • After setup, the Catalyst+HD™ system will continue to monitor patient posture and position during treatment
  • Real-time intra-fraction motion monitoring
  • Patient movements over threshold immediately trigger an alarm and/or beam hold
  • Continuous calculation of isocentric shift, enabling detection of slower relaxation or sliding movements

Want to know more?

Hear from our clinical partners

“C-RAD allows us to in real time manage the motion that the patient has as they breathe… C-RAD will allow us to completely avoid the heart and deliver the radiation precisely accurately to their breasts only…”

nch logo
Stephen S. Nigh, M.D.

Radiation Oncology, Medical Director of Cancer Services,
Northwest Community Healthcare, US

Related resources from learning center

Retos y cambios en el flujo de trabajo con Sentinel 4DCT

| Catalyst, Webinar | No Comments
La simulación 4DCT se está convirtiendo rápidamente en un procedimiento estándar en radioterapia, principalmente en radiocirugía, una vez que la respiración del paciente y los movimientos de los volúmenes blanco…

Flujo de trabajo con SGRT, ¿Sustituye la IGRT?

| Catalyst, Webinar | No Comments
Los retos de una transición dependen de entender y conocer el sistema así como el cambio que tendrá el flujo de trabajo. El éxito de la transición depende enteramente de…

Implementación de un sistema SGRT, retos y preparación del personal

| Catalyst, Webinar | No Comments
Siempre se debe considerar el cambio de mentalidad y los retos tecnológicos que existen alrededor de la puesta en marcha de cualquier sistema, en este caso al tratarse de un…

联系我们

有什么可以帮到您?

联系我们了解产品或服务支持

给我们留言

联系全球办公室

我们在美国、中国、德国、法国和瑞典设有服务支持团队

联系我们